Auscultatory gap

Also found in: Dictionary, Medical, Financial, Encyclopedia.

An auscultatory gap, also known as the silent gap,[1] is a period of diminished or absent Korotkoff sounds during the manual measurement of blood pressure. It is associated with reduced peripheral blood flow caused by changes in the pulse wave.[2] The improper interpretation of this gap may lead to blood pressure monitoring errors,[1][2] such as an underestimation of systolic blood pressure and/or an overestimation of diastolic blood pressure. In order to correct for an auscultatory gap, the radial pulse should be monitored by palpation.[3] It is therefore recommended to palpate and auscultate when manually recording a patient's blood pressure.[3] Typically, the blood pressure obtained via palpation is around 10 mmHg lower than the pressure obtained via auscultation. In general, the examiner can avoid being confused by an auscultatory gap by always inflating a blood pressure cuff to 20-40 mmHg higher than the pressure required to occlude the brachial pulse.[4][5]

Cause

There is evidence that auscultatory gaps are related to carotid atherosclerosis, and to increased arterial stiffness in hypertensive patients.[1][3] This appears to be independent of age.[2] Another cause is believed to be venous stasis within the limb that is being used for the measurement. Although these observations need to be confirmed prospectively, they suggest that auscultatory gaps may have prognostic relevance.[6]

History

Auscultatory gap was first officially noted in 1918.[1]

References

  1. ^ a b c d Gibson, PaulC. (November 1927). "The Silent Gap in Auscultatory Estimations of Blood Pressure". The Lancet. 210 (5437): 1012–1014. doi:10.1016/s0140-6736(01)35491-0. ISSN 0140-6736.
  2. ^ a b c Rodbard, Simon; Ciesielski, Jan (1959-08-01). "A relation between the auscultatory gap and the pulse upstroke". American Heart Journal. 58 (2): 221–230. doi:10.1016/0002-8703(59)90339-4. ISSN 0002-8703.
  3. ^ a b c Irisawa, Hiroshi; Goki, Hiroshi; Yukutake, Masato (1962-09-01). "Cause of the disappearance of the auscultatory sound in indirect blood pressure measurements". American Heart Journal. 64 (3): 308–313. doi:10.1016/0002-8703(62)90144-8. ISSN 0002-8703.
  4. ^ Askey, John (1974). "The Auscultatory Gap in Sphygmomanometry". Annals of Internal Medicine. 80 (1): 94–7. doi:10.7326/0003-4819-80-1-94. PMID 4589516.
  5. ^ Bickley, Lynn S.; Szilagyi, Peter G. (2013). Bates' guide to physical examination and history-taking (11th ed.). Philadelphia: Wolters Kluwer Health/Lippincott Williams & Wilkins. p. 122. ISBN 978-1-60913-762-5. OCLC 801810287.
  6. ^ Cavallini, M. Chiara; et al. (1996-05-15). "Association of the Auscultatory Gap with Vascular Disease in Hypertensive Patients". Annals of Internal Medicine. 124 (10): 877–883. CiteSeerX 10.1.1.694.3515. doi:10.7326/0003-4819-124-10-199605150-00003. PMID 8610916.
This article is copied from an article on Wikipedia® - the free encyclopedia created and edited by its online user community. The text was not checked or edited by anyone on our staff. Although the vast majority of Wikipedia® encyclopedia articles provide accurate and timely information, please do not assume the accuracy of any particular article. This article is distributed under the terms of GNU Free Documentation License.

Copyright © 2003-2025 Farlex, Inc Disclaimer
All content on this website, including dictionary, thesaurus, literature, geography, and other reference data is for informational purposes only. This information should not be considered complete, up to date, and is not intended to be used in place of a visit, consultation, or advice of a legal, medical, or any other professional.